Dynaco M2 Cleanroom high speed door
The Dynaco M2 CLEANROOM is designed for an interior environment type cleanroom class 10,000 to 100,000 (according to Fed/Std 209 E) demanding a limitation of the leak flow at a difference in pressure up to 0.82 lbs/sq ft. (drafts of 19 MPH indicative, not including any multiplication coefficients taking into account the configuration of the building). The M2 CLEANROOM door is recommended for inside environments requiring cleanroom class contamination control.
White
Blue
Grey
Yellow
Black
Orange
Red
Green
Standard Dimensions
18′ W x 18′ H
Opening Speed
96 in/s
Closing Speed
48 in/s
Operating Type
Gear driven, push-pull movement
Side Guide
Made of structural channels or 3 1/8″ x 1 5/8″ x 1/8″ in steel + frame cover or 3 1/8″ x 1 5/8″ x 0.078″ in stainless steel (optional).
Inner Side Guide
Polyethylene (PE-UHMW 1000); outer section 7/8” x 1 9/16” fixed at the base of structural channels with closed nuts, without springs. The design provides a tight superior seal for demanding clean room applications.
Side Guide Covers
Galvanized Steel
Drum
In steel, diameter 4″ x 0.078″, shafts in steel. Shafts and flanges are welded interior and exterior of the drum.
Door Curtain
Very resistant PVC (27 oz/sq.yd). Available in different colors and provided with side sealing zippers (Section 5/8” x 1/2”). The soft bottom edge design is completely enclosed and hermetically sealed for ease of cleaning.
Motor
Without brake, with 4 poles, controlled by a variable speed drive. Power: 2 HP. Protection degree NEMA 4.
Gearbox
Size 50 for a motor of 1 HP and gear reduction ratio 1/7; size 63 for 2 HP.
Detectors
An infrared photocell, installed inside the frame and detecting the presence of a pedestrian or a vehicle, immediately opens the door and keeps it open as long as the presence is detected. Height of the photocell: 12” from the floor. (Optional: up to maximum 24” upon request).
A bottom edge detector opens the door when it hits an obstacle during the closing cycle. This detector is positioned at the bottom part of the curtain.
Power Supply
Standard: single phase 208-230 VAC, three phase 208-230 VAC, three phase 460 VAC. Optional: three phase 575 VAC.
Frequency: 50-60 Hz. Fuses to be provided by the customer: 10 A for a motor of 1 HP and 16 A for 2 HP.
Space Requirements
All indicated dimensions are net: the space necessary for mounting and maintenance has to be provided. Reduced dimensions: upon request.
- Designed for cleanroom class operations requiring limitation in leak flow of up to 0.82 lbs per square foot per federal standard 209E.
- Maximum standard dimensions 18′ x 18′.
- Curtain made of PVC reinforced vinyl.
- Operating speed up to 96″/sec.
- Infrared photocell in side guides.
- Soft bottom edge.
- Pneumatic bottom edge detector.
- Designed for interior contamination control in the pharmaceutical, electronic, hospital, laboratory or other controlled environments.
- Pharmaceutical
- Electronic
- Hospitals
- Laboratories